JM Modern HikaShop - шаблон joomla Видео
In
(06-1) 619-8321
Promega

GloMax® Discover System

GloMax Discover1
GloMAx Disccover2
Now Available… GloMax® Discover
Be one of the first to experience Promega's newest integrated detection system.

This ready-to-use multimode detection system includes: high-performance luminescence, fluorescence, UV-Visible absorbance, BRET and FRET, two-color filtered luminescence and kinetic measurement capabilities.
The instrument is operated by an integrated Tablet PC, which provides quick and easy navigation through the control options. Exporting your results is made seamless with a variety of options, including exporting to your local data network. The GloMax® Discover software will provide many of the required technical elements of a part 11 compliant system (user authentication and authorization, data integrity and protection, electronic signatures and audit trails) when used with the appropriate laboratory workflow.

ÁRAJÁNLATOT, INFORMÁCIÓT KÉREK!

Performance

The GloMax® Discover System delivers maximum flexibility with minimal user intervention.

Easy-To-Use

Choose from preloaded Promega protocols or customize your own.

Build custom protocols using the intuitive drag-and-drop interface.

Export data to a network, cloud or any drive desired. EasyToUse

MinimalIntervention

Minimal Manual Intervention

Filter paddles and automatic filter switching allow easy two-color multiplexing assays or kinetic studies.

Quick read-speeds for high efficiencies in your laboratory.

Compatible for 3rd party automation control.

Superior Sensitivity

Plate mask (aperture control) for switching between 96-well and 384-well plates.

Low cross-talk between wells gives you better, more usable results.

Broad dynamic range of the instrument extends the linear range of your assay.

SuperiorSensitivity

Quality

IQ/OQ Service available.

Provides many of the required technical elements of a part 11 compliant system (user authentication and authorization, data integrity and protection, electronic signatures and audit trails) when used with the appropriate laboratory workflow.

Quality

 

 

 

Műszaki specifikációk
Instrument Specifications
Detection Modes Luminescence, Fluorescence Intensity, UV-Visible Absorbance, Filtered Luminescence, BRET and FRET
Sample Format 6, 12, 24, 48, 96 and 384-well plates
Tablet PC Windows®8 Tablet PC with USB connection to instrument
Read Speed 96-well plate: less than 1 minute; 384-well plate: less than 3 minutes
Automation Compatibility Hardware and software accessible to 3rd party hardware/software control, including LIMS.
Dimensions 18.5in (46.9cm) width
19.5in (46.5cm) depth
10in (25.4cm) height without Tablet and PC mounted
16in (35.5cm) height with Tablet and PC mounted
Weight Approximately 60lbs. (27kg)
Power Requirements 120VA, 50/60 HZ
Warranty 1-year parts and labor warranty included
Regulatory Compliance For Research Use Only. Not for use in Diagnostic Procedures
Luminescence Module Specifications
Detector Top-reading, head-on photon counting photomultiplier tube (PMT)
Wavelength Range 350–700nm
Detection Limit 3 × 10-21 moles of luciferase
Linear Dynamic Range 9 logs
Cross-talk Less than 3 × 10-5 (white, 96-well plate, Corning 3912)
Filtered Luminescence Built-in filter paddle
Fluorescence Module Specifications
Detector PIN-photodiode
Light Source Wavelength-matched LED
Read Position Top reading
Wavelengths selection Filter module with 5 standard excitation and emission filters. Empty filter positions are available for custom excitation and emission wavelengths.
Wavelengths included UV (Ex: 365nm, Em: 415-445nm) Blue (Ex: 475nm, Em: 500-550nm) Green (Ex: 525nm, Em: 580-640nm) Red (Ex: 625nm, Em: 660-720nm) AFC (Ex: 405nm, Em: 495-505nm)
Detection Limit 2fmol fluorescein/200μl
Linear Dynamic Range >6 logs (assay dependent)
UV-Visible Absorbance Module Specifications
Detector Top-reading, head-on photon counting photomultiplier tube (PMT)
Light Source Xenon flash lamp
Spectra Range 200-600nm
Filter Wheel 9 absorbance filters included
Wavelengths included 230, 260, 280, 320, 405, 450, 490, 560 and 600nm 10nm band pass
Detection Limit 0.01 O.D.
Dynamic Range 0-4.0 O.D.
Injector System Specifications
Number of injectors (optional) Two injectors
Dispense Volume Range 5-200μl in 1μl increments
Plate Compatibility 6, 12, 24, 48, and 96-well plates
Injection Speed 20-500μl per second
Waste Collection Tray Volume Approximately 50ml
Void Volume 500μl
Shaker System Specifications
Shaking Pattern Linear or orbital patterns
Shaking Intensity 100-500 cycles/minute
Heating System Specifications
Temperature Range Ambient to 45°C
PC Requirements
Operating System Windows® 8, 64 bit, with USB connection to instrument
RAM 2GB
Disk Space 64GB
Other Requirements Microsoft.NET 4.0 Framework (full version), Microsoft Excel 2013 Professional
Applikációk
  • Bioassays
  • Measuring the ADCC Reporter Bioassay Complete Kit (WIL2-S) Signal on the GloMax® Discover System
  • Cell Health and Metabolism
  • Measuring the Output of the CytoTox-Fluor™ Cytotoxicity Assay on the GloMax® Discover System
  • Measuring the ONE-Glo + Tox Luciferase Reporter and Cell Viability Assay on the GloMax® Discover System
  • Measuring Cell Viability Using the CellTiter-Glo® Cell Viability Assay and GloMax® Discover System
  • Measuring P450-Glo™ Assays on the GloMax® Discover System
  • Measuring Bacterial Cell Viability Using the BacTiter-Glo™ Assay and GloMax® Discover System
  • Measuring Fluorescence Using the Apo-ONE® Homogeneous Caspase-3/7 Assay with the GloMax® Discover System
  • Measuring Fluorescence Using the CellTiter-Blue® Cell Viability Assay with the GloMax® Discover System
  • Measuring Fluorescence Using the ApoTox-Glo™ Triplex Assay With the GloMax® Discover System
  • Measuring the Output of the CytoTox-Fluor™ Cytotoxicity Assay on the GloMax® Discover System
  • Measuring Fluorescence Using the ApoLive-Glo™ Multiplex Assay with the GloMax® Discover System
  • Measuring Absorbance Using the CellTiter 96® AQueous One Solution Cell Proliferation Assay with the GloMax® Discover System
  • Measuring Luminescence of the Kinase-Glo® Luminescent Kinase Assay using the GloMax® Discover System 
  • Measuring Fluorescence from Cy®5 Dye using the GloMax® Discover System
  • Measuring Fluorescence from Cy®3 Dye using the GloMax® Discover System
  • Measuring Cell Viability Using the CellTiter-Fluor™ Cell Viability Assay and GloMax® Discover System 
  • Measuring Cytotoxicity Using the CytoTox-Glo™ Cytotoxicity Assay and GloMax® Discover System 
  • DNA and RNA Quantification
  • Measuring ssDNA Concentration Using the QuantiFluor® ssDNA System with the GloMax® Discover System
  • Measuring RNA Concentration Using the QuantiFluor® RNA System with the GloMax® Discover System
  • Measuring dsDNA Concentration Using the QuantiFluor® dsDNA System with the GloMax® Discover System
  • Automating dsDNA Quantitation Using Promega QuantiFluor® Chemistries and Tecan Freedom EVO® System 
  • Drug Discovery
  • Measuring Luminescence using the GloSensor™ cAMP Assay with the GloMax® Discover System
  • Measuring cAMP Levels Using the cAMP-Glo™ Assay and GloMax Discover System 
  • Reporter Assays
  • Measuring the ONE-Glo™ Luciferase Assay System on the GloMax® Discover System
  • Measuring Filtered Luminescence of the Chroma-Glo™ Luciferase Assay System using the GloMax® Discover System
  • Measuring Luminescence of the Renilla-Glo® Luciferase Assay System using the GloMax® Discover System
  • Measuring Luminescence of the Steady-Glo® Luciferase Assay System using the GloMax® Discover System
  • Measuring Luminescence of the Bright-Glo™ Luciferase Assay System using the GloMax® Discover System
  • Measuring the Dual-Glo® Luciferase Assay on the GloMax® Discover System
  • Measuring the Dual-Luciferase Reporter Assay on the GloMax® Discover
  • Measuring the Luciferase Assay System on the GloMax® Discover
  • Measuring Protein Concentration
  • Measuring Protein Concentration Using the BCA Protein Assay with the GloMax® Discover System
  • Measuring Protein Concentration Using the 660nm Protein Assay with the GloMax® Discover System
Tartozékok, kiszerelések

GloMax® Discover System

GM3000
 

Available Separately

ProductCatalog #

Light Plate, ABS/Fluor

E6532

GloMax® Dual Injectors with Pumps

GM3030

GloMax® Discover Luminescence Filter Paddle

GM3011

GloMax® Discover Fluorescence Filter Paddle

GM3012

GloMax® Discover or Explorer Installation Qualification

SA1104

GloMax® Discover or Explorer Operational Qualification

SA1105

GloMax® Discover or Explorer Installation and Operational Qualification

SA1106

GloMax® Discover or Explorer Instrument Rental, 1 month

SA1098

GloMax® Discover Standard Service Agreement

SA4000

GloMax® Discover or Explorer Preventive Maintenance

SA4030
Videók, ismertetők
  • GloMax Discover Video

  • Articles

  • Automated cytotoxicity profiling
  • Measuring Cell Viability Using the CellTiter-Fluor™ Cell Viability Assay and GloMax® Discover System
  • Measuring cAMP Levels Using the cAMP-Glo™ Assay and GloMax® Discover System
  • Measuring Cytotoxicity Using the CytoTox-Glo™ Cytotoxicity Assay and GloMax® Discover System
  • Measuring Luminescence of the Bright-Glo™ Luciferase Assay System using the GloMax® Discover System

blue down arrowForgalmazott termékeink gyártói - keressen gyártó szerint a logóra kattintva